LG ZMD120AR

Figure 1.5. ZMD120AR

ZMD120AR


The following is a readout of the meter with the non printable characters hidden and quite mode: ./readmeter.py -cq > LG.txt

/LGZ4\2ZMD1202140.I05
F.F(02000000)
0.0(   21441)
0.1.0(41)
0.1.0*04(13-05-01 00:00)
0.1.0*03(13-04-01 00:00)
0.1.0*02(13-03-01 00:00)
0.1.0*01(13-02-01 00:00)
0.1.0*12(13-01-01 00:00)
0.1.0*11(12-12-01 00:00)
0.1.0*10(12-11-01 00:00)
0.1.0*09(12-10-01 00:00)
0.1.0*08(12-09-01 00:00)
0.1.0*07(12-08-01 00:00)
0.1.0*06(12-07-01 00:00)
0.1.0*05(12-06-01 00:00)
1.8.1(0009277*kWh)
1.8.1*04(0009068)
1.8.1*03(0008830)
1.8.1*02(0008606)
1.8.1*01(0008360)
1.8.1*12(0008137)
1.8.1*11(0007897)
1.8.1*10(0007704)
1.8.1*09(0007510)
1.8.1*08(0007318)
1.8.1*07(0007136)
1.8.1*06(0006967)
1.8.1*05(0006769)
1.8.2(0007399*kWh)
1.8.2*04(0007248)
1.8.2*03(0007101)
1.8.2*02(0006958)
1.8.2*01(0006785)
1.8.2*12(0006602)
1.8.2*11(0006451)
1.8.2*10(0006292)
1.8.2*09(0006140)
1.8.2*08(0006025)
1.8.2*07(0005872)
1.8.2*06(0005742)
1.8.2*05(0005572)
2.8.1(0000000*kWh)
2.8.1*04(0000000)
2.8.1*03(0000000)
2.8.1*02(0000000)
2.8.1*01(0000000)
2.8.1*12(0000000)
2.8.1*11(0000000)
2.8.1*10(0000000)
2.8.1*09(0000000)
2.8.1*08(0000000)
2.8.1*07(0000000)
2.8.1*06(0000000)
2.8.1*05(0000000)
2.8.2(0000000*kWh)
2.8.2*04(0000000)
2.8.2*03(0000000)
2.8.2*02(0000000)
2.8.2*01(0000000)
2.8.2*12(0000000)
2.8.2*11(0000000)
2.8.2*10(0000000)
2.8.2*09(0000000)
2.8.2*08(0000000)
2.8.2*07(0000000)
2.8.2*06(0000000)
2.8.2*05(0000000)
1.8.0(0016676*kWh)
2.8.0(0000000*kWh)
0.9.1(18:41:47)
0.9.2(00-01-12)
C.3.0(00000000)
C.2.1(09-07-21 09:58)

The first line identifies the meter and contains the maximum baudrate.

Since the meter has lost its time from its internal clock, it reports an error with FF.

0.0 shows the identification number of the meter

0.1.0 indicates the resets of the energy meter including date and time

1.8.1 is the input energy at tariff 1 containing the total and the last 12 months

1.8.2 is the input energy at tariff 2 containing the total and the last 12 months

2.8.1 is the output energy at tariff 1 containing the total and the last 12 months

2.8.2 is the output energy at tariff 2 containing the total and the last 12 months

0.9.1 is the current time

0.9.2 is the current date

C.3.0 is the active energy constant for a pulse

C.2.1 is date and time of last parameterization

Figure 1.6. Read out

ZMD120AR data